www.neotek.ch

This is an old revision of the document!


Table of Contents

SGI O2 PSU Fan

Why

Simple - the old Panaflow unit was loud and vibrates due to worn out bearings. But don't hope for a silent O2, its still pretty loud.

How

  • Pull power cord (this is the first thing you have to do, if you take something apart!!)
  • Pull PSU
  • remove the three marked screws

  • Lift the base off using your thumb. It requires a bit of force; then flip it open.

  • remove the fan screw

  • What looks like a rivet isn't one, so don't just snap it off or pull it out. Using a slender object—one that isn't too sharp—you can push the inner section inward, allowing the entire piece to be pulled out without damaging it.

  • Unplug the old fan and pull the wires out of the plug.

  • cut the wire of the new fan to the right length and press the wires in the old plug. You need some force, doubble check the polaritiy!

  • Attach the air guide pieces to the new fan.

  • Put the fan back in position (hier some closeup how it is int the right position)